Electric resistance glass lehr and glazing kilns furnaces with ir circulation 

 

Electric lehrs with air circulation BETA
Suitable for cooling technologies of glass production of differenet shapes and size within the limits of the furnacr passage according to a preselected curve. 

They are provided with air circulation fans, so that a uniform temperature is manitained in the whole furnace and the quality of the product is high. electric heating of the furnace ensures a hygienic environment.

The furnace are of the unit construction tzpe and can be built into an appropriate systemconsistent with the required technoogy and number of glass products to be cooled. The thermocoules are small and can be mutually combined and arranged in the heating tunnel in such a manner that the correct heat conditions are obtained in the furnace They have another advantage, being easy t replace after a short time interval and after disconnecting one heating zone during operation of the furnace.

 

 

Type

Belt width  

Width

Temperature

Speed of belt

Operation width Height of passage Height of belt Lenght  
F           E D
mm mm °C m / min mm mm mm mm

BETA  500 

700 1.900 600 0,05-0,9 500 500 950 3.000

BETA  1.000

1.200 2.400 600 0,05-0,9 1.000 500 950 3.000

BETA  1.600  

1.800 3.000 600 0,05-0,9 1.600 400 950 3.000

BETA  2.200

2.400 3.600 600 0,05-0,9 2.200 400 950 3.000
Lenght of heating tunnel A mm Heating and cooling part lengths, as well as rated heating power, depend on temperature curve, products size and required capacity. 

Lenght of coolong tunnel

B mm
Lenght of charging table C mm
Lenhgt of furnace L mm
Input   kW

 

                       

Electric glazing kilns with air circulation BETA  V
These kilns serve for underglazing coloured, ice-etched, gold and other patterns.

The furnace are box.shaped and of the unit construction type. They are built as continuous kilns with a delivery wire belt, electric resistance heating and air circulation. 

They consist of the following htere main parts: the hetaing section, the coolong section and air circulation 

 

Type

Belt width  

Width

Temperature

Speed of belt

Operation width Height of passage Height of belt Lenght 
F           E D
mm mm °C m / min mm mm mm mm

BETA V 500 

700 1.900 700 0,05-0,9 500 500 950 1.820

BETA V 1.000

1.200 2.400 700 0,05-0,9 1.000 500 950 1.820

BETA V 1.600  

1.800 3.000 700 0,05-0,9 1.600 400 950 3.000

BETA V 2.200

2.400 3.600 700 0,05-0,9 2.200 400 950 3.000
Lenght of heating tunnel A mm Heating and cooling part lengths, as well as rated heating power, depend on temperature curve, products size and required capacity. 

Lenght of coolong tunnel

B mm
Lenght of charging table C mm
Lenhgt of furnace L mm
Input   kW