| Electric resistance glass lehr and glazing kilns furnaces with ir circulation |
| Electric lehrs with air circulation |
| Suitable
for cooling technologies of glass production of differenet shapes and size
within the limits of the furnacr passage according to a preselected curve.
They are provided with air circulation fans, so that a uniform temperature is manitained in the whole furnace and the quality of the product is high. electric heating of the furnace ensures a hygienic environment. The furnace are of the unit construction tzpe and can be built into an appropriate systemconsistent with the required technoogy and number of glass products to be cooled. The thermocoules are small and can be mutually combined and arranged in the heating tunnel in such a manner that the correct heat conditions are obtained in the furnace They have another advantage, being easy t replace after a short time interval and after disconnecting one heating zone during operation of the furnace.
|
||
|
|
||
|
Type |
Belt width |
Width |
Temperature |
Speed of belt |
Operation width | Height of passage | Height of belt | Lenght |
| F | E | D | ||||||
| mm | mm | °C | m / min | mm | mm | mm | mm | |
|
BETA 500 |
700 | 1.900 | 600 | 0,05-0,9 | 500 | 500 | 950 | 3.000 |
|
BETA 1.000 |
1.200 | 2.400 | 600 | 0,05-0,9 | 1.000 | 500 | 950 | 3.000 |
|
BETA 1.600 |
1.800 | 3.000 | 600 | 0,05-0,9 | 1.600 | 400 | 950 | 3.000 |
|
BETA 2.200 |
2.400 | 3.600 | 600 | 0,05-0,9 | 2.200 | 400 | 950 | 3.000 |
| Lenght of heating tunnel | A | mm | Heating and cooling part lengths, as well as rated heating power, depend on temperature curve, products size and required capacity. | |||||
|
Lenght of coolong tunnel |
B | mm | ||||||
| Lenght of charging table | C | mm | ||||||
| Lenhgt of furnace | L | mm | ||||||
| Input | kW | |||||||

| Electric glazing kilns with air circulation |
| These kilns serve for
underglazing coloured, ice-etched, gold and other patterns.
The furnace are box.shaped and of the unit construction type. They are built as continuous kilns with a delivery wire belt, electric resistance heating and air circulation. They consist of the following htere main parts: the hetaing section, the coolong section and air circulation |
||
|
|
||
|
Type |
Belt width |
Width |
Temperature |
Speed of belt |
Operation width | Height of passage | Height of belt | Lenght |
| F | E | D | ||||||
| mm | mm | °C | m / min | mm | mm | mm | mm | |
|
BETA V 500 |
700 | 1.900 | 700 | 0,05-0,9 | 500 | 500 | 950 | 1.820 |
|
BETA V 1.000 |
1.200 | 2.400 | 700 | 0,05-0,9 | 1.000 | 500 | 950 | 1.820 |
|
BETA V 1.600 |
1.800 | 3.000 | 700 | 0,05-0,9 | 1.600 | 400 | 950 | 3.000 |
|
BETA V 2.200 |
2.400 | 3.600 | 700 | 0,05-0,9 | 2.200 | 400 | 950 | 3.000 |
| Lenght of heating tunnel | A | mm | Heating and cooling part lengths, as well as rated heating power, depend on temperature curve, products size and required capacity. | |||||
|
Lenght of coolong tunnel |
B | mm | ||||||
| Lenght of charging table | C | mm | ||||||
| Lenhgt of furnace | L | mm | ||||||
| Input | kW | |||||||